Skip to content
REFRIGERANT · PURE SUBSTANCE

R-134a

A pure HFC substance, in a 12 kg refillable cylinder. This page carries the GWP published in Annex I, the regulatory status of the gas, the transport data, and what you have to declare in order to buy it.

Checked dataLast verified: 2026-09-16Data version 2026-08-26

GWP100
1,430Annex I, Section 1 — published value
UN number
UN 3159ADR 2.2
Net content
12 kg
Cylinder
Refillable
Gas under pressure
Warning
  • H280: Contains gas under pressure; may explode if heated.
UN 3159 · ADR 2.2

Identity and composition

R-134a is a single substance, not a blend. The 1430 figure is read straight from Annex I, Section 1 rather than calculated, which is why there is no blend tolerance and no weighted average here.

The substance
ComponentChemical nameBy weightGWP100
R-134a1,1,1,2-tetrafluoroethane100 %1,430
Designation
R-134a
Also written
R-134a · R134a · HFC-134a · 134a
Composition per
ANSI/ASHRAE Standard 34 — refrigerant designationsR-134a (100.0)
Tolerance
Not applicable — single substance.
GWP method
Regulation (EU) 2024/573, Annex I, Section 1 — the published value for the substanceAnnex I, Section 1: HFC-134a = 1430
Unrounded value
1,430Rounded value: 1,430

Source: Open Regulation (EU) 2024/573 on EUR-Lex

Work out the tonnes of CO2 equivalentOpens the F-Gas calculator with R-134a already selected.

Where this gas is used

The equipment categories in which this gas is commonly found.

  • Mobile air conditioning (MAC)Vehicle air conditioning systems registered before the change to R-1234yf.
  • Medium-temperature commercial refrigerationDisplay cabinets, cold rooms and prep counters in shops and professional kitchens.
  • Water chillersCentrifugal and screw units in office buildings, hospitals and industry.
  • Commercial refrigerators and freezersSelf-contained equipment in operation and under servicing.
  • Heat pumps and compressed-air dryersMedium-temperature applications in industry and in buildings.

This list describes ordinary market use. It does not confirm that the gas is suitable for a particular machine. Compatibility, working pressure and oil come from the equipment manufacturer's documentation and the nameplate.

Regulatory status

The Regulation (EU) 2024/573 thresholds that touch this gas directly.

ArticleApplies toGWP thresholdFromFor R-134a
Article 13(3)Refrigeration equipment2,500January 1, 2025Allowed
Article 13(4)Air conditioning and heat pumps2,500January 1, 2026Allowed
Article 13(5)Stationary refrigeration, chillers excluded750January 1, 2032May no longer be used from this date
Annex IV, point 9 (placing on the market)Single split systems below 3 kg (placing on the market)750January 1, 2025New equipment banned from this date
HFC quota

Every component is an Annex I, Section 1 gas. Bulk gas placed on the EU market consumes HFC quota.

General information, taken from the EgoLog guide checked against official sources. It is not an assessment of your job and does not replace the text of the regulation.

Read the full ban timetable

Safety and hazards

Gas under pressure
Warning
  • H280: Contains gas under pressure; may explode if heated.
UN 3159 · ADR 2.2

Not classified as a flammable gas: no flame pictogram and no H221 statement.

Concrete handling, storage, first-aid and spillage measures come from the safety data sheet of the product actually delivered.

Open the SDS

The legal SDS matching the delivered batch and the language of the destination country is sent to the buyer before dispatch. The document here is the EgoLog public reference.

Cylinder and package

Net refrigerant
12 kg
Cylinder type
Refillable

The amount included for the cylinder is shown with the price and comes from the shop.

Single-use cylinders are banned in the EU.

Why non-refillable cylinders are banned

Ask for a bulk priceNeed a larger quantity?

Who may buy

Fluorinated refrigerant gas is not an ordinary product. Article 11(6) of Regulation (EU) 2024/573 limits who may buy it for installation, maintenance, servicing or repair — and it binds the seller too.

The two declarations available at checkout

Technical use / installation and servicing

A valid F-Gas certificate is required for charging, installation, maintenance, servicing, repair or recovery. At checkout you enter the certificate holder, the number and the issuing country.

Distributor / resale

I am buying the sealed product for resale without carrying out technical work on the gas or equipment. The option is available to a company, sole trader or professional entity.

The declaration is recorded with the order. The details may be checked before dispatch.

This page does not decide whether you may buy. That is settled at checkout, against the declaration you sign.

Who may buy and sell refrigerant gas

Documents

The legal SDS matching the delivered batch and the language of the destination country is sent to the buyer before dispatch. The document here is the EgoLog public reference.

What the buyer receives

  • Invoice and order confirmation
  • Delivery note / packing list with product, quantity, batch and container serial numbers
  • The actual supplier's SDS in the mandatory language of the destination, plus an English copy
  • TPED and refillable container compliance details, where applicable
  • Certificate of analysis (CoA) where one is issued for the batch

All EgoLog documents

Related guides

EgoLog guides checked against official sources, tied directly to this product.

Delivery and invoicing

Delivery times, countries and costs are shown in the shop and at checkout.

Invoicing and VAT treatment are shown in the shop and on the invoice.

See the delivery terms